Application Note
CS5480/84/90 Measurement Accuracy
vs. IEC Standards
1. Introduction
Cirrus Logic’s CS5480, CS5484, and CS5490 energy measurement ICs benefit from on-chip, high-performance, 24-
bit ADC converters in conjunction with its digital calibration and compensation algorithms. This application note pres-
ents accuracy results from testing the CS5480. The CS5484 and CS5490 uses the same core technology as the
CS5480. Testing results of the CS5484 and CS5490 show nearly identical results.
The CS5480 has world-leading accuracy over an extensive, dynamic range. This application note cites measure-
ments of active energy, reactive energy, and I
RMS
load performance acquired from the CS5480 using three different
types of current sensor: Rogowski coil, current transformer (CT), and shunt. A comparison between the CS5480
measurements and the IEC 62053 standards is presented. This comparison shows that the CS5480 meets IEC
62053-22 class 0,2S standards for active energy and IEC 62053-23 class 2 standards for reactive energy. Compar-
ison with the ANSI C12.20 standard is not included in this application note because the ANSI standard is less strin-
gent than the IEC 62053 standard, so it is implied that the CS5480 meets it.
2. Test Setup
The following diagram illustrates the connections between the PPS400.3 power source, PRS400.3 power reference,
current sensor, CDB5480U board (+3.3V DC power supply), and a host PC.
Power Source
U
n
I
b
CS5480
VIN 1+
VIN 1-
N3
U3
CDB5480U
I3
PPS400.3
Power Reference
U3
N3
I3
PRS400.3
Energy Pulses
+3.3V DC Power Supply
+3.3V GND
USB
M
C
U
DO1
TX
RX
PC
CDB5480U GUI
CAMCAL
®
for
WINDOWS
RS232
RS232
Current
Sensor
METER
SH2003
IIN1 -
IIN1 +
27n
27n
1K100
1K100
27n
27n
GND
IIN1-
IIN1+
J1
V+
V-
GND
27n
27n
LINE 1
GND
J4
422 K 422K 422K422K
1K
Figure 1. Test Setup Connection Diagram
AN362
MAR’12
AN362REV1
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Application Note

Copyright  Cirrus Logic, Inc. 2012(All Rights Reserved)Cirrus Logic, Inc.http://www.cirrus.comApplication NoteCS5480/84/90 Measurement Accuracyvs. IE

Seite 2 - • Phase compensation

AN36210 AN362REV14.3Accuracy Results for IRMS Load Current PerformanceFigure 9. IRMS Load Current PerformanceLoad Current (A)Current Dynamic Range (x

Seite 3 - = 2(80A) at 50Hz

AN362AN362REV1 115. Accuracy Test with Shunt, Un = 240V and Ib(max) = 2.5(100A) at 50HzA 100μΩ shunt is used as the current sensor. When the meter is

Seite 4 - = 2 (80 A) at 50 Hz

AN36212 AN362REV15.1Accuracy Results for Active Energy Load PerformanceFigure 11. Active Energy Load Performance vs IEC 62053-22 Class 0,2S StandardP

Seite 5

AN362AN362REV1 13Figure 12. Reactive Energy Load Performance vs IEC 62053-23 Class 2 StandardPower Factor Load Current (A) Current Dynamic Range (x:1

Seite 6 - 3.3Accuracy Results for I

AN36214 AN362REV15.2Accuracy Results for IRMS Load Current PerformanceFigure 13. IRMS Load Current Performance6. SummaryThe CS5480 supports three cur

Seite 7

AN362AN362REV1 157. Revision History Revision Date ChangesREV1 MAR 2012 Initial Release.

Seite 8

AN36216 AN362REV1Contacting Cirrus Logic SupportFor all product questions and inquiries contact a Cirrus Logic Sales Representative. To find one neare

Seite 9

AN3622 AN362REV1The Cirrus Logic CDB5480U demonstration board and current sensor form a single-phase, two-wire energy meter.The CDB5480U software is i

Seite 10 - Load Current Performance

AN362AN362REV1 33. Accuracy Test with Rogowski Coil, Un = 240V and Ib(max) = 2(80A) at 50HzPulse PA3202NL is used as the current sensor. The secondary

Seite 11 - = 2.5(100A) at 50Hz

AN3624 AN362REV13.1Accuracy Results for Active Energy Load PerformanceFigure 3. Active Energy Load Performance vs. IEC 62053-22 Class 0,2S StandardPo

Seite 12 - = 2.5 (100 A) at 50 Hz

AN362AN362REV1 53.2Accuracy Results for Reactive Energy Load PerformanceFigure 4. Reactive Energy Load Performance vs IEC 62053-23 Class 2 StandardPo

Seite 13

AN3626 AN362REV13.3Accuracy Results for IRMS Load Current PerformanceFigure 5. IRMS Load Current PerformanceLoad Current (A)Current Dynamic Range (x:

Seite 14 - 5.2Accuracy Results for I

AN362AN362REV1 74. Accuracy Test with Current Transformer CT, Un = 240V and Ib(max) = 2.5(100A) at 50HzTaehwatrans TZ76V is used as the current sensor

Seite 15 - 7. Revision History

AN3628 AN362REV14.1Accuracy Results for Active Energy Load PerformanceFigure 7. Active Energy Load Performance vs IEC 62053-22 Class 0,2S StandardPow

Seite 16 - 16 AN362REV1

AN362AN362REV1 94.2Accuracy Results for Reactive Energy Load PerformanceFigure 8. Reactive Energy Load Performance vs IEC 62053-23 Class 2 StandardPo

Kommentare zu diesen Handbüchern

Keine Kommentare